Appendix
EMC Information
Essential performance of FlexScan T1781 is to display images and operate functions normally.
CAUTION
The FlexScan T1781 requires special precautions regarding EMC and need to be installed, put into
service and used according to the following information.
Do not use any cables other than the cables that provided or speci ed by us.
Using other cables may cause the increase of emission or decrease of immunity.
Cable Length: Max. 2m
Do not put any portable and mobile RF communications equipment close to the FlexScan T1781.
Doing so may affect the FlexScan T1781.
The FlexScan T1781 should not be used adjacent to or stacked with other equipment. If adjacent or
stacked use is necessary, the equipment or system should be observed to verify normal operation
in the con guration in which it will be used.
Anyone who connects additional equipment to the signal input part or signal output parts,
con guring a medical system, is responsible that the system complies with the requirements of IEC/
EN60601-1-2.
Guidance and manufacturers declaration - electromagnetic emissions
TheFlexScanT1781isintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuseroftheFlexScanT1781shouldassurethatitisusedinsuchanenvironment.
Emission test Compliance Electromagnetic environment - guidance
RFemissions
CISPR11/EN55011
Group1 TheFlexScanT1781usesRFenergyonlyforitsinternalfunction.
Therefore,itsRFemissionareverylowandarenotlikelytocauseany
interferenceinnearbyelectronicequipment.
RFemissions
CISPR11/EN55011
ClassB TheFlexScanT1781issuitableforuseinallestablishments,includingdomestic
establishmentsandthosedirectlyconnectedtothepubliclow-voltagepower
supplynetworkthatsuppliesbuildingsusedfordomesticpurposes.
Harmonicemissions
IEC/EN61000-3-2
ClassD
Voltageuctuations/
ickeremissions
IEC/EN61000-3-3
Complies
Guidance and manufacturers declaration - electromagnetic immunity
TheFlexScanT1781isintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuseroftheFlexScanT1781shouldassurethatitisusedinsuchanenvironment.
Immunity test IEC/EN60601 test
level
Compliance level Electromagnetic environment - guidance
Electrostatic
discharge(ESD)
IEC/EN61000-4-2
±6kVcontact
±8kVair
±6kVcontact
±8kVair
Floorsshouldbewood,concreteorceramictile.
Ifoorsarecoveredwithsyntheticmaterial,the
relativehumidityshouldbeatleast30%.
Electricalfast
transient/burst
IEC/EN61000-4-4
±2kV
forpowersupplylines
±1kV
forinput/outputlines
±2kV
forpowersupplylines
±1kV
forinput/outputlines
Mainspowerqualityshouldbethatofatypical
commercialorhospitalenvironment.
Surge
IEC/EN61000-4-5
±1kVline(s)toline(s)
±2kVline(s)toearth
±1kVline(s)toline(s)
±2kVline(s)toearth
Mainspowerqualityshouldbethatofatypical
commercialorhospitalenvironment.
Voltagedips,short
interruptionsand
voltagevariationson
powersupplyinput
lines
IEC/EN61000-4-11
<5%U
T
(>95%dipin
U
T
)for0.5cycle
40%U
T
(60%dipinU
T
)
for5cycles
70%U
T
(30%dipinU
T
)
for25cycles
<5%U
T
(>95%dipin
U
T
)for5sec
<5%U
T
(>95%dipin
U
T
)for0.5cycle
40%U
T
(60%dipin
U
T
)for5cycles
70%U
T
(30%dipin
U
T
)for25cycles
<5%U
T
(>95%dipin
U
T
)for5sec
Mainspowerqualityshouldbethatofatypical
commercialorhospitalenvironment.Ifthe
useroftheFlexScanT1781requirescontinued
operationduringpowermainsinterruptions,it
isrecommendedthattheFlexScanT1781be
poweredfromanuninterruptiblepowersupplyor
abattery.
Powerfrequency
(50/60Hz)
magneticeld
IEC/EN61000-4-8
3A/m 3A/m Powerfrequencymagneticeldsshouldbeat
levelscharacteristicofatypicallocationina
typicalcommercialorhospitalenvironment.
NOTEU
T
isthea.c.mainsvoltagepriortoapplicationofthetestlevel.